B-63944EN/02 PROGRAMMING 20.AXIS CONTROL FUNCTIONS
- 589 -
Synchronous error compensation and synchronous error check
are restarted.
6. Reset the correction mode alarm.
- Method of recovery using normal operation
Use this method when switching between synchronous operation and
normal operation by using an input signal.
Use the procedure below for recovery from alarm SV0005.
1. Set SYNCx/SYNCJx (with x representing a slave axis number)
to 0 to select normal operation.
2. Set a value greater than the current value in the parameter No.
8314 for specifying a maximum allowable synchronous error,
then reset the alarm.
3. Make a movement along the master axis or slave axis by using
the manual handle so that the machine coordinates of the master
axis and slave axis match to a maximum possible extent.
4. Return the value of parameter No. 8314 for specifying a
maximum allowable synchronous error to the original value.