1. DISPLAY AND OPERATION
B--63005EN/02
138
(2)Remaining service time
The remaining service time of an item (the time allowed before the
item is replaced) is determined by count--down and displayed under
“Remaining service time.” When the remaining service time
decreases to a specified percentage (specified in parameter No. 8911)
of the service life or lower, it is displayed in red.
Count--down continues even after the service life has expired.
First place the cursor on the remaining service time of a target
registration number, enter a desired remaining service time value
using numeric keys, then press soft key [INPUT] (or the
INPUT
key).
Pressing soft key [+INPUT] adds the newly specified remaining
service time to the previously specified remaining service time.
The valid data range for the remaining service time is: 0 to (service
life)
After soft key [CLEAR] is pressed, pressing soft key [EXEC] sets the
remaining service time with the same value as for the service life.
NOTE
1 An attempt to set up the remaining service time for a non--
registered item or an item for which the service life has not
been set up results in the warning message “EDIT
REJECTED”.
2 An attempt to enter a value that is out of the valid data range
results in the warning message “DATA IS OUT OF RANGE”.
3 An attempt to enter a value that would make the remaining
service time 0 or lower, it is clamped at 0.
4. Pressing soft key [TYPE] results in the warning message
“EDIT REJECTED”.
(3)Count type
The type of a selected count method is specified under “Count type.”
After the cursor is placed on the count type of a target registration
number, pressing soft key [TYPE] displays the next count type as a
soft key. Select it and press soft key [EXEC].
Soft key Meaning Display
[NO CNT] Not counting (suspended). —
[ALL] Always count. All times
[PWR ON] Count while the power is supplied. Power--on time
[ RUN ] Count while operation is under way. Operating
[ CUT ] Count while cutting is under way. Cutting