4.2. Setting of ROTARY SWITCH and SHORT TERMINAL
in case of connecting to FANUC PANEL i or Intelligent terminal
The power-on start sequence can be modified using rotary switch on the board and
short terminal (SW5) on FANUC PANEL i or Intelligent terminal.
setting of
rotary
switch
short terminal
(SW5)
description
0
OPEN
Setting for maintenance.
The start menu is displayed. It is
possible to start boot and IPL from
FANUC PANEL i or Intelligent
terminal.
1
OPEN
Setting for usual operation.
The start menu is not displayed.
It is impossible to start boot or IPL
from FANUC PANEL i or Intelligent
terminal.
Do not turn on/off
the CNC power if
FANUC Intelligent
terminal is
powered on.
* It’s possible if
PANEL i.
2
SHORT
The CNC and FANUC PANEL i or Intelligent terminal are
started independently of each other without handshake.
CNC
CNC is available if FANUC PANEL i or Intelligent
terminal is not turned on or not connected. (Display for CNC
and MDi or Operation panel etc. are needed to
operate.)
The start menu is not displayed if FANUC PANEL i or
Intelligent terminal is connected and turned on.
FANUC PANEL i, Intelligent terminal
FANUC PANEL i or Intelligent terminal is available if
CNC is not turned on or not connected.
Temperature management function of FANUC PANEL i
or Intelligent terminal doesn’t work. Please make sure
that the temperature is proper for FANUC PANEL i or
Intelligent terminal.
The start menu is not displayed and it is impossible to start
boot or IPL from FANUC PANEL i or Intelligent
terminal if CNC is connected and turned on.
This position must be used at maintenance only.
EDIT.
FANUC LTD
SHEE
DRAW. NO. CUST
TITLE
013
DESCRIPTIONDESIG.DATE
B-63005EN/02-1