G. FSSB START--UP PROCEDURE/
MATERIALS
B--63005EN/02
APPENDIX
812
The FSSB setting screen displays FSSB--based amplifier and axis
information, and allows amplifier and axis information to be set.
1 Press function key
SYSTEM
.
2 Pressing the continuous menu key
several times displays
[FSSB].
3 Pressing soft key [FSSB] switches the screen display to the amplifier
setting screen (or the FSSB setting screen selected previously), and
displays the following soft keys:
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
Thereare threetypes of FSSB setting screens: theamplifier settingscreen,
axis setting screen, and amplifier maintenance screen.
Pressing soft key [AMP] switches the screen display to the amplifier
setting screen.
Pressing soft key [AXIS] switches the screen display to the axis setting
screen.Pressing soft key [MAINT] switches the screen display to the
amplifier maintenance screen.
The amplifier setting screen displays slave information divided into
amplifier information and pulse module information.
(AMPLIFIER SETTING) O1000 N00001
NO.
1 A1-L ∼ SVM-HV 40AL 1 X
2 A1-M ∼ SVM 12A 2 Y
3 A2-L ϒ SVM 40A 3 Z
4 A3-L ∼ SVM 20A 4 A
5 A3-M ∼ SVM 40A 5 B
7 A4-L ∼ SVU 240A 6 C
NO. PCB ID
6 M1 A 0000 DETECTOR(8AXES)
8 M2 B 12AB
>_
MDI **** *** *** 13:11:56
[ AMP ][ AXIS ][ MAINT ][ ][ (OPRT) ]
The amplifier setting screen displays the items below.
D NO.: Slave number
The serial numbers for to up to ten slaves (up to eight amplifiers and
up to two pulse modules) connected via the FSSB are displayed
sequentially. A younger number is assigned to a slave closer to the
CNC.
D AMP: Amplifier type
Amplifier type information starts with the character A, which stands
for “amplifier.” The character A is followed by the ordinal number of
an amplifier counted from the amplifier closest to the CNC, then is
followed by a letter indicating which axis of the amplifier is used (L
for the first axis, and M for the second axis).
G.9
FSSB DATA DISPLAY
G.9.1
Amplifier Setting
Screen