1. DISPLAY AND OPERATION
B--63005EN/02
68
Detail
number
MeasureCause
Parameter
number
8254
8255
8256
1825 The internal value of the position gain has
overflowed.
Use the position gain magnification func-
tion.
10016
10019
2200 bit 0 The internal value of a parameter used to
detect runaway has overflowed.
Do not use the runaway detection func-
tion (specify bit 0 = 1).
10043 1815#1
2010#2
A full--closed loop has been set up for a
linear motor (except for the Series 9080).
A full--c losed loop cannot be specified for
linear motors.
10053 2018#0 The scale reverse connection bit has
been set up for a linear motor.
The scale reverse connection bit cannot
be used for linear motors.
10062 2209#4 The amplifier in use does not support the
HC alarm avoidance function.
If you want to use this amplifier, reset the
function bit listed at the left to 0.
If you want to use the HC alarm avoid-
ance function, use an amplifier that sup-
ports it.
360 Cumulative command pulse count (NC)
DGN
[Data type] Two--word axis
[Unitofdata] Detection unit
[Valid data range] 99999999 to --99999999
Indicates the cumulative count of movement commands distributed from
the CNC since the power was switched on.
361 Cumulative compensation pulse count (NC)
DGN
[Data type] Word axis
[Unitofdata] Detection unit
[Valid data range] 32767 to --32767
Indicates the cumulative count of compensation pulses (backlash
compensation, pitch error compensation, etc.) distributed from the CNC
since the power was switched on.
362 Cumulative command pulse count (SV)
DGN
[Data type] Two--word axis
[Unitofdata] Detection unit
[Valid data range] 99999999 to --99999999
Indicates the cumulative count of movement command andcompensation
pulses received at the servo section since the power was switched on.
D Error detection