B–63510EN/01
4. DESCRIPTION OF PARAMETERS
141
5015
Distance (XP) betweeen reference position and X axis + contact surface
5016
Distance (XM) betweeen reference position and X axis – contact surface
5017
Distance (ZP) betweeen reference position and Z axis + contact surface
5018
Distance (ZM) betweeen reference position and Z axis – contact surface
[Data type] 2–word
[Unit of data]
Increment system IS–B IS–C Unit
Millimeter input 0.001 0.0001 mm
Inch input 0.0001 0.00001 inch
[Valid data range] –99999999 to 99999999
These parameters are related to the function of input of tool offset value
measured B.
They set the distance (with sign) between the measurement reference
position and sensor contact surface. For an axis under diameter
programming, set it by a diameter value.
Xm
Xp
Z–axis +contact
face
Z–axis –contact face
X–axis –contact face
X–axis +contact face
Zm
Zp
+Z
+X
mesurement
reference
position
Fig.4.15 Distance along X and Z Axes from the Reference Position to +/– Contact Surfaces