4. DESCRIPTION OF PARAMETERS
B–63510EN/01
174
#7
5400
#6
XSC
#5 #4 #3 #2 #1 #0
RIN
RINSCR
[Data type] Bit type
RIN Coordinate rotation angle command (R)
0 : Specified by an absolute method
1 : Specified by G90 or G91
XSC Axis scaling and programmable mirror image
0 : Invalidated (The scaling magnification is specified by P.)
1 : Validated
SCR Scaling magnification unit
0 : 0.00001 times (1/100,000)
1 : 0.001 times
#7
5401
#6 #5 #4 #3 #2 #1 #0
SCLx
[Data type] Bit axis
SCLx Scaling for every axis
0 : Invalidated
1 : Validated
5410
Angular displacement used when no angular displacement is specified for coor-
dinate system rotation
[Data type] 2–word
[Unit of data] 0.001 degrees
[Valid data range] –360000 to 360000
This parameter sets the angular displacement for coordinate system
rotation. When the angular displacement for coordinate system rotation is
not specified with address R in the block where G68 is specified, the
setting of this parameter is used as the angular displacement for
coordinate system rotation.
4.18
PARAMETERS OF
SCALING/COORDINA
TE ROTATION