4. DESCRIPTION OF PARAMETERS
B–63510EN/01
158
5214 Setting of an allowable rigid tapping synchronization error range
5215
Setting of an allowable rigid tapping synchronization error range for the second
spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 0 to 32767
Each of these parameters is used to set an allowable synchronization error
range between a spindle used for rigid tapping and the tapping axis.
If the value set with each parameter is exceeded, servo alarm No.411
(excessive error during movement) for the tapping axis is issued. When 0
is set, a synchronization error check is not made.
NOTE
When rigid tapping is performed using the second spindle
• When the SPR parameter (bit 1 of parameter No.5204) is
set to 0, the setting of parameter No.5214 is applied to the
second spindle, as well as to the first spindle.
• When the SPR parameter (bit 1 of parameter No.5204) is
set to 1, the settings of parameter No.5215 are applied to
the second spindle, respectively.