4. DESCRIPTION OF PARAMETERS
B–63510EN/01
172
5351
Positional deviation limit imposed during spindle movement in rigid tapping using
the second spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed during
spindle movement in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.
5352
Positional deviation limit imposed while the tapping axis is stopped in rigid tap-
ping using the second spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed while
the tapping axis is stopped in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.
5353
Positional deviation limit imposed while the spindle is stopped in rigid tapping
using the second spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed while
the spindle is stopped in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.