B–63510EN/01
4. DESCRIPTION OF PARAMETERS
91
MKP When M02, M30, or EOR(%) is executed during MDI operation, the
created MDI program is:
0 : Erased automatically.
1 : Not erased automatically.
NOTE
If the MER parameter (bit 6 of parameter No.3203) is 1,
executing the last block provides a choice of whether to
automatically erase a created program.
#7
3205
#6 #5 #4 #3 #2 #1
CHG
#0
COL
[Data type] Bit
COL When a program is displayed or output, any colons (:) in the comments of
the program are:
0 : Converted to letter O
1 : Displayed or output as is
CHG When the change function of the extended edit function is used:
0 : Once the user has decided whether to make a change, the cursor is
moved to the target position.
1 : The cursor is moved to the change source, after which the user can
choose whether to make a change.
3210 Password
[Data type] 2–word axis
This parameter sets a password for protecting program Nos. 9000 to 9999.
When a value other than zero is set in this parameter and this value differs
from the keyword set in parameter No.3211, bit 4 (NE9) of parameter
No.3202 for protecting program Nos. 9000 to 9999 is automatically set to
1. This disables the editing of program Nos. 9000 to 9999. Until the value
set as the password is set as a keyword, NE9 cannot be set to 0 and the
password cannot be modified.
NOTE
1 The state where password = 0 and password = keyword is
referred to as the locked state. When an attempt is made to
modify the password by MDI input operation in this state, the
warning message “WRITE PROTECTED” is displayed to
indicate that the password cannot be modified. When an
attempt is made to modify the password with G10
(programmable parameter input), P/S alarm No.231 is issued.
2 When the value of the password is not 0, the parameter
screen does not display the password. Care must be taken
in setting a password.