4. DESCRIPTION OF PARAMETERS
B–63510EN/01
228
#7
8301
#6 #5 #4 #3 #2 #1 #0
SOF
[Data type] Bit
SOF The synchronization funciton in simple synchronous control is:
0 : Not used.
1 : Used.
8311 Axis number of master axis in synchronous control
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte axis
<For the T Series>
Select a master axis and slave axis in simple synchronous control. Set a
master axis number with a slave axis. For the parameters for the first axis
and the second axis of parameter No.8311, set the following:
Units digit of the parameter for the first axis –>
Set the axis number of a master axis for the first axis.
Tens digit of the parameter for the first axis –>
Set the axis number of a master axis for the second axis.
Units digit of the parameter for the second axis –>
Set the axis number of a master axis for the third axis.
Tens digit of the parameter for the second axis –>
Set the axis number of a master axis for the fourth axis.
Number Tens digit Units digit
First axis Second axis First axis
Second axis Fourth axis Third axis
Note that the axis number settings are as follows:
0 –> First axis, 1 –> Second axis, 2 –> Third axis, 3 –> Fourth axis
NOTE
For an axis for which 0 is set, the first axis serves as the
master axis. So, when the control signal for the axis is set
to 1, the first axis serves as a master axis, and synchronous
control is exercised.
<For the M Series>
[Valid data range] 0, 1 to Number of controlled axes
Select a master axis and slave axis in simple synchronous control. Set a
master axis number with the slave axis side. The axis number settings are:
1 –> First axis, 2 –> Second axis, 3 –> Third axis, 4 –> Fourth axis. Up to
one pair can be specified.
4.40
PARAMETERS OF
SIMPLE
SYNCHRONOUS
CONTROL