4. DESCRIPTION OF PARAMETERS
B–63510EN/01
18
XIK When LRP, bit 1 of parameter No.1401, is set to 0, namely, when
positioning is performed using non–linear type positioning, if an
interlock is applied to the machine along one of axes in positioning,
0: The machine stops moving along the axis for which the interlock is
applied and continues to move along the other axes.
1: The machine stops moving along all the axes.
IDG When the reference position is set without dogs, automatic setting of the
IDGx parameter (bit 0 of parameter No.1012) to prevent the reference
position from being set again is:
0 : Not performed.
1 : Performed.
#7
IPR1004
#6 #5 #4 #3 #2 #1
ISC
#0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
ISC The least input increment and least command increment are set.
ISC Least input increment and least command increment Symbol
0 0.001 mm, 0.001 deg, or 0.0001 inch IS–B
1 0.0001 mm, 0.0001 deg, or 0.00001 inch IS–C
IPR Whether the least input increment for each axis is set to a value 10 times as
large as the least command increment is specified, in increment systems
of IS–B or IS–C at setting mm.
0: The least input increment is not set to a value 10 times as larg as the
least command increment.
1: The least input increment is set to a value 10 times as large as the least
command increment.
If IPR is set to 1, the least input increment is set as follows:
Input increment Least input increment
IS–B 0.01 mm, 0.01 deg, or 0.0001 inch
IS–C 0.001 mm, 0.001 deg, or 0.00001 inch
NOTE
Inputs in inches are multiplied by 10.
#7
1005
#6 #5
EDMx
EDMx
#4
EDPx
EDPx
#3
HJZx
#2 #1
DLZx
DLZx
#0
ZRNx
ZRNx
[Data type] Bit axis
ZRNx When a command specifying the movement except for G28 is issued in
automatic operation (MEM, RMT, or MDI) and when a return to the
reference position has not been performed since the power was turned on
0 : An alarm is generated (P/S alarm 224).
1 : An alarm is not generated.