B–63465EN/01
1. DISPLAY AND OPERATION
9
XE0: (Reserved)
XE1: Broken wire in the slave port
XE2: Broken wire in the master port
XE3: External EMG input
#7
330
#6 #5 #4 #3
EXT
#2
DUA
#1
ST1
#0
ST0
#7
332
#6 #5 #4 #3
EXT
#2
DUA
#1
ST1
#0
ST0
:
:
#7
348
#6 #5 #4 #3
EXT
#2
DUA
#1
ST1
#0
ST0
ST0, ST1: The type code of the slave actually connected is indicated.
ST1 ST0 Type Address
0 0 A Servo amplifier
0 1 (B: RESERVE) (Not provided currently)
1 0 C Separate detector interface unit
1 1 (RESERVE) (Not provided currently)
DUA 0 : The corresponding slave is not used for the first axis of the 2–axis
amplifier.
1 : The corresponding slave is used for the first axis of the 2–axis
amplifier.
EXT 0 : No corresponding slave exists.
1 : The corresponding slave exists.
#7
331
#6 #5
DMA
#4
TP1
#3
TP0
#2
HA2
#1
HA1
#0
HA0
#7
333
#6 #5
DMA
#4
TP1
#3
TP0
#2
HA2
#1
HA1
#0
HA0
:
:
#7
349
#6 #5
DMA
#4
TP1
#3
TP0
#2
HA2
#1
HA1
#0
HA0
HA0,HA1,HA2: The host LSI address that is set as the DMA destination is indicated.
TP0,TP1: The type code of the set slave is indicated. (See the description of ST0 and
ST1 above.)
DMA: The setting that determines whether to allow a DMA to occur is displayed.
NOTE
A combination of diagnostic indications No. 330 and No.
331 corresponds to a single slave unit for the FSSB. Up to