B–63465EN/01
3. INPUT AND OUTPUT OF DATA
71
The Digital Servo Adapter memorized the following data.
Save a backup copy of the latest data to the flash memory card or an I/O
unit beforehand, while the controller is running normally.
(1)Paramter
Be sure that data input/output cannot be done in an alarm status.
The parameters necessary for data input/output are as follows:
#7
0000
#6 #5 #4 #3 #2 #1
ISO
#0
ISO 0 : Output with EIA code
1 : Output with ISO code (FANUC cassette)
0020 Selection of I/O channel
0 : Channel 1
1 : Channel 1
If the I/O CHANNEL is 0, the relevant parameters are Nos. 101, 102, and
103.
If the I/O CHANNEL is 1, the relevant parameters are Nos. 111, 112, and
113.
#7
NFD0101
#6 #5 #4 #3
ASI
#2 #1 #0
SB2
NFD 0 : Feed is output when data is output.
1 : Feed is not output when data is output.
ASI l 0 : EIA or ISO code is used for input data.
1 : ASCII code is used.
SB2 0 : No. of stop bits is 1.
l 1 : No. of stop bits is 2.
0102 pecification number of input/output device
Table 3.2.1 Set value and Input/Output Device
Set value
Input/Output device
0 RS–232–C (except the following for connection with a PC)
3 FANUC Handy File
0103 Baud Rate
7: 600 9: 2400 11: 9600
8: 1200 l10: 4800 12: 19200 [BPS]
3.2
INPUTTING/
OUTPUTTING DATA
3.2.1
Confirming the
Parameters Required for