3. INPUT AND OUTPUT OF DATA
B–63465EN/01
72
1. Set emergency stop.
2. Select the parameter display screen by
key.
3. Press the
key.
4. While parameter, is being output, the display appears as below.
>&0001 00000000
WRITE
When output is conducted to the floppy, the program is output as the new
file after the files existing in the floppy.
When P/S alarm (No.086) occurs during program output, the floppy is
restored to the condition before the output.
To efficiently use the memory in the cassette or card, output the program
by setting parameter NFD (No.0101#7 or, No.0111#7) to 1. This
parameter makes the feed is not output, utilizing the memory efficiently.
Head searching with a file No. is necessary when a file output from the
Digital Servo Adapter to the floppy is again input to the Digital Servo
Adapter memory or compared with the content of the Digital Servo
Adapter memory. Therefore, immediately after a file is output from the
Digital Servo Adapter to the floppy, record the file No. on the memo.
1. Press the EMERGENCY STOP button on the machine side.
2. The parameter screen is selected by pressing the
key.
3. Set PWE on the setting screen to 1. Alarm PS100 is displayed at this
time.
4. Press the
READ
key.
5. NC parameters are input to the memory by this operation. Normally,
alarm PS000 will activate after completion of parameter reading.
Nomally, P/S alarm 000 is generated after parameters have finished
being read in.
6. Set PWE on the setting parameter to 0.
7. Turn on the Digital Servo Adapter power again.
3.2.2
Outputting Parameters
D Procedure (DPL/MDI)
Explanations
(Output to a floppy)
D File output location
D An alarm while a
program is output
D Efficient use of memory
D On the memo record
3.2.3
Inputting Parameters
D Procedure (DPL/MDI)