4. DIGITAL SERVO
B–63465EN/01
74
This section describes how to set initial servo parameters, which is used
for field adjustment of machine.
1. Turn on power at the emergency stop condition.
2. Input data required for initial setting using the cursor and page key.
(1)Initial set bit
#7
2000
#6 #5 #4 #3
PRMCAL
#2 #1
DGPRM
#0
PLC01
PRMCAL 1 : Turns to 1 when the initial setting is done.
The following parameters are set automatically in accordance with the
no. of pulses of pulse coder:
PRM 2043(PK1V), PRM 2044(PK2V), PRM 2047(POA1),
PRM 2053(PPMAX),PRM 2054(PDDP),
PRM 2056(EMFCMP),
PRM 2057(PVPA), PRM 2059(EMFBAS),
PRM 2074(AALPH),PRM 2076(WKAC)
DGPRMl 0 : Initial setting of digital servo parameter is done.
1 : Initial setting of digital servo parameter is not done.
PLC01 0 : Values of parameter 2023 and 2024 are used as they are:
1 : Values of parameter 2023 and 2024 are multiplied by 10.
(2)Motor number
For a series servo motor
Model name a 1/3000 a 2/2000 a 2.5/3000 a 3/3000
Drawing number 0371 0372 0374 0123
Format number 61 46 84 15
Model name a 6/2000 a 6/3000 a 12/2000 a 12/3000 a 22/1500
Drawing number 0127 0128 0142 0143 0146
Format number 16 17 18 19 27
Model name a 22/2000 a 22/3000 a 30/1200 a 30/2000 a 30/3000
Drawing number 0147 0148 0151 0152 0153
Format number 20 21 28 22 23
Model name a 40/FAN a 40/2000 a 65 a 100 a 150
Drawing number 0158 0157 0331 0332 0333
Format number 29 30 39 40 41
Model name a 300/1200 a 300/2000 a 300/2000 a 400/1200
Drawing number 135 337 137 136
Format number 113 111 115 114
Model name a 400/2000 a 400/2000 a 1000/2000
Drawing number 338 138 131
Format number 112 116 117
4.1
INITIAL SETTING
SERVO