4. DESCRIPTION OF PARAMETERS
B–63670EN/01
18
15080 Piercing power
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
Specify a piercing power.
15081 Initial frequency of piercing
[Data type] Word
[Unit of data] Hz
[Valid data range] 5 to 2000
Specify the initial frequency of piercing.
15082 Incremental value of piercing frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 0 to 2000
Specify a value by which the piercing frequency is incremented.
15083 Initial duty ratio of piercing
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
Specify the initial duty ratio of piercing.
15084 Incremental value of piercing duty ratio
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 100
Specify a value by which the piercing duty ratio is incremented.
15085 Piercing step time
[Data type] Word
[Unit of data] Millisecond
[Valid data range] 0 to 32767
Specify a piercing step time.
4.5
PIERCING
CONDITIONS