4. DESCRIPTION OF PARAMETERS
B–63670EN/01
50
15530 Reference displacement
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] Parameter No. 15531 to parameter No. 15532
The setting determines the reference distance from the tip of the quill to
the workpiece to be controlled in Z–axis tracing control.
NOTE
This parameter can be set on the tracer setting screen.
15531 Lower limit on reference displacement
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] –32768 to 32767
[Standard setting] 0
Specify the minimum value that can be specified as the reference
displacement for Z–axis tracing control.
15532 Upper limit on reference displacement
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] –32768 to 32767
[Standard setting] 1000
Specify the maximum value that can be specified as the reference
displacement for Z–axis tracing control.
15533 Displacement causing large displacement alarm
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] 0 to 32767
[Standard setting] 1200
When a value specified as the reference displacement exceeds this setting
in Z–axis tracing control, a large displacement alarm is raised.
15534 Tracing displacement on workpiece surface
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] 0 to 32767
This setting indicates the displacement from the surface of the workpiece
to the zero point in tracing control.
4.22
SETTINGS RELATED
TO TRACING