4. DESCRIPTION OF PARAMETERS
B–63670EN/01
66
15642 Output address of transfer status from TB to extended battery–powered memory
[Data type] Word
[Unit of data]
[Valid data range] 0 to 65528
When an R or S command is specified in the teaching box, the start
address, byte count, completion code, and control bit of the data sent from
the teaching box are set at the address specified in parameter No.15642.
Address specified in parameter No.15642
Start address of data +0
Byte count +2
Completion code +4
Control Bit +6
Control Bit +6
#7 #6 #5 #4 #3 #2 #1 #0
MSTBA
When MSTBA is set to 1, the R or S command is masked.
(If an R or S command is specified while MSTBA is set to 1, an alarm
completion code is output.)
15643 DI size
15644 DO size
[Data type] Byte
[Unit of data] Byte
[Valid data range] 1 to 15 (When 0 is specified, the extension function is disabled.)
Specify the sizes of DI and DO.
Specify the DI size in parameter No.15643 and the DO size in parameter
No.15644. Starting from the address specified in parameter No.15638 and
parameter No.15639, the DI and DO areas of the specified sizes are
assigned. This parameter is valid, when the bit 1 (TBX) of parameter
No.15641 is set to 1.
Internal relay area
DI
The size is specified in parameter
No.15643.
Start address
Specified in parameter No.15638
Start address
Specified in parameter No.15639
DO
The size is specified in parameter
No.15644.