15212 Upper limit on power when the duty ratio is not clamped
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
When the duty ratio is not clamped to 50% according to parameter No.
15213 and when the specified power exceeds this setting after power
calibration and power feedback addition, the actual power is clamped to
this setting. When 0 is specified, the value of parameter No. 15207 is
assumed.
15213 Criterion for clamping the duty ratio
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 7000
When the product of the specified power and override exceeds this setting,
the duty ratio is always limited to 50%, and the peak value is clamped to
the value specified in parameter No. 15210. When 0 is specified, the value
of parameter No. 15210 is assumed.
15214 Maximum CW–YAG laser frequency
[Data type] Word
[Unit of data] Hz
[Valid data range] 0 to 32767
The frequency of the CW–YAG laser oscillator is clamped to this setting.
15215 Power input calibration coefficient
[Data type] Word
[Unit of data] W
[Valid data range] 102 (0.1 2
10
) to 10240 (10 2
10
) (When 0 is specified, 1024 (1 2
10
)
is assumed.)
Specify a power input calibration coefficient.
15216 Time constant of power display filter
[Data type] Word
[Unit of data] Millisecond
[Valid data range] 0 to 32767
Specify a time constant for the filter that suppresses flickering of the
power display.