4. DESCRIPTION OF PARAMETERS
B–63670EN/01
48
15510 Integral time constant
[Data type] Word
[Unit of data] Millisecond
[Valid data range] 0 to 32767
[Standard setting] 0
The integral time constant is used for displacement integration in Z–axis
tracing control.
15511 Integral calibration zero width
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] 0 to 32767
[Standard setting] 0
The setting is used as a displacement to disable integration in Z–axis
tracing control. The integration is not performed when |(displacement
specified as a reference value)| x (integral calibration zero width).
15512 Integral clamp value
[Data type] Word
[Unit of data] 0.001 mm
[Valid data range] 0 to 32767
[Standard setting] 0
The setting is the integral clamp value for displacement integration in
Z–axis tracing control.
4.20
SETTINGS RELATED
TO TRACING
(INTEGRATION)