B–63670EN/01
4. DESCRIPTION OF PARAMETERS
33
15230 Value for determining stop of power feedback control
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 32767
If the difference in specified power value between the current block and
previous block during automatic operation is the setting in this parameter
or more, power feedback control is stopped.
NOTE
Specified power values refer to values obtained as a result
of the reflection of power override; they are not values just
specified in machining programs. Therefore, when a power
value specified in a machining program is 1000 W and the
power override is 150%, for example, the specified power
value is as follows:
Specified power value = 1000 1.5 = 1500 W
15231 Power feedback mask time at change in specified power
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 65535
When a change in specified power value is detected, power feedback
control is stopped for the time set in this parameter.
15232 Allowable variation in specified power (dead zone width)
[Data type] Word
[Unit of data] W
[Valid data range] 0 to 65535
If a change in specified power value is smaller than the value set in this
parameter, power feedback control continues on the assumption that there
is no change in specified power.
NOTE
Specified power values refer to values obtained as a result
of the reflection of power override; they are not values just
specified in machining programs. Therefore, when a power
value specified in a machining program is 1000 W and the
power override is 150%, for example, the specified power
value is as follows:
Specified power value = 1000 1.5 = 1500 W