B–62443EN–2/03
4. OPERATION
129
The loader control PMC and machine control PMC communicate via 96
or 192 signals.
An F address signal of the loader control PMC informs the contents of the
corresponding G address signal of the machine control PMC.
An F address signal of the machine control PMC indicates the contents
of the corresponding G address signal of the loader control PMC.
G0212 to G0219
G0252 to G0255
F0212 to F0219
F0252 to F0255
G1212 to G1219
G1252 to G1255
F1212 to F1219
F1252 to F1255
F0212 to F0219
F0252 to F0255
G0212 to G0219
G0252 to G0255
F1212 to F1219
F1252 to F1255
G1212 to G1219
G1252 to G1255
Machine
control
PMC
96 signals
96 signals
96 signals
96 signals
Loader
control
PMC
Loader–NC communication signals
<F0212 to F0219, F0252 to F0255, F1212 to F1219, F1252 to F1255>
[Classification] Output signal
[Function] Reports the contents of the corresponding G address
signal of the other PMC.
[Output conditions]
A bit is set to 0 when
D The corresponding bit of the G address of the
other PMC is 0.
A bit is set to 1 when
D The corresponding bit of the G address of the
other PMC is 1.
(Example) When bit 0 in G212 of the NC (machine) PMC is set
to 1, bit 0 in F212 of the loader PMC is also set to 1.
Data
#7 #6 #5 #4 #3 #2 #1 #0
No.
8102 S19
[Data type] : Bit
S19 The loader and NC use:
4.4.3
Loader–NC
Communication
Signals
D Overview
D Signals
D Parameters