B–62443EN–2/03
A. PARAMETERS
161
#7 #6 #5 #4 #3 #2 #1 #0
8101 MWB
Data type : Bit
MWB A waiting M code is:
0 : Buffered.
1 : Not buffered.
#7 #6 #5 #4 #3 #2 #1 #0
8102 S19
Data type : Bit
S19 The PMC of the loader and NC use:
0 : 96 communication signals.
1 : 192 communication signals. (G1212 to G1219, G1252 to
G1255, F1212 to F1219, and F1252 to F1255 are used.)
NOTE
When this parameter is changed, a power–down request
occurs. Only the loader supports this parameter.
8110 Waiting M code range (minimum value)
Data type : 2 words
Valid data range : 0 and 100 to 99999999
This parameter specifies the minimum value of the waiting M code.
The waiting M code range is specified using parameter 8110 (minimum
value) and parameter 8111 (maximum value).
(parameter 8110) v (waiting M code) v (parameter 8111)
NOTE
A value of 0 indicates that the waiting M code is not used.
8111 Waiting M code range (maximum value)
Data type : 2 words
Valid data range : 0 and 100 to 99999999
This parameter specifies the maximum value of the waiting M code