5.MACRO VARIABLES B-63943EN-2/01
- 102 -
-Caution
CAUTION
Specifying variable #3000 from a conversational
macro or auxiliary macro causes automatic
operation to stop due to an alarm.
Displaying an operator message using variable #3006
Specifying variable #3006 from a conversational macro or auxiliary
macro causes a message to be displayed on the external operator
message screen and automatic operation to stop.
Specifying the variable from an execution macro has the same effect
as specifying it from a custom macro program.
-Caution
CAUTION
Specifying variable #3006 from a conversational
macro or auxiliary macro causes automatic
operation to stop.
P-CODE macro UI/UO separation function
It is possible to use different signals in P-CODE macros from those
used in user programs, as interface input signals, which can be read
from system variables #1000 to #1015, #1032, #1110 to #1115, and
#1132, and interface output signals to be sent.
By setting bit 3 (EUI) of parameter (No. 9035) to 1, the signals
written and read to and from system variables in P-CODE macros
(conversational macros, auxiliary macros, and execution macros)
become the above-mentioned interface signals.
NOTE
ven if this function is used, the UI/UO signals in
user programs (other than P-CODE macros) are
ordinary interface signals.
- Variables #1000 to #1015 and #1032
By reading system variables #1000 to #1015 and #1032, the states of
the input signals for P-CODE macros can be determined.
- Variables #1100 to #1115 and #1132
By using system variables #1100 to #1115 and #1132, the output
signals for P-CODE macros can be read and written.