B-63943EN-2/01 3.EXECUTION MACRO FUNCTION
- 61 -
Compile parameter PCDC(No. 9163#2)
01
0
User macro calls using G65, M98, G66, and G66.1 only are allowed.
Other types of calls are disabled.
- For user program calls
Calls using G65, M98, G66, and G66.1 only
are allowed.
Other types of calls are disabled.
- For execution macro calls
- From a user program called using a G
code, an execution macro can be called
using a code other than G codes (or
using an axis address).
- From a user program called using a
code other than G codes (or using an
axis address), an execution macro can
be called using a G code.
- Other types of calls (G code → G code,
code other than G codes → code other
than G codes) are disabled.
- For user program calls and execution
macro calls
A user program or execution macro can be
called under the same condition as for an
execution macro call performed when bit 6
(GMP) of parameter (No. 6008) is set to 1,
and bit 2 (PCDC) of compile parameter
(No. 9163) is set to 0.
Parameter GMP
(No.6008#6)
1
- After an execution macro is called, the user
program cannot be called again. (The
duplicate calling of a user program is
disabled.)
- After an execution macro is called, the user
program can be called again. (The
duplicated calling of a user program is
allowed.)