6.MACRO EXECUTOR FUNCTION B-63943EN-2/01
- 180 -
6.5.2 Function
Line open G330
- Format
G330 Pp Bb Ss Cc ;
P : Interface number and control method of the
input/output device for the foreground
= 1 : Hard flow control with RS-232-C1
= 2 : Hard flow control with RS-232-C2
= 11 : Reception control with RS-232-C1
= 12 : Reception control with RS-232-C2
= 21 : Transmission control with RS-232-C1
= 22 : Transmission control with RS-232-C2
= 31 : File control with RS-232-C1
= 32 : File control with RS-232-C2
B : Baud rate of the input/output device
1: 50b/s 2: 100b/s 3: 110b/s
4: 150b/s 5: 200b/s 6: 300b/s
7: 600b/s 8: 1200b/s 9: 2400b/s
10: 4800b/s 11: 9600b/s 12: 19200b/s
S : Number of stop bits and parity bits
= 1 : 1 stop bit, without parity
= 2 : 2 stop bits, without parity
=11 : 1 stop bit, odd parity
=12 : 2 stop bits, odd parity
=21 : 1 stop bit, even parity
=22 : 2 stop bits, even parity
C : Output code specification
= 1 : ASCII code
= 2 : ISO code
= 3 : EIA code
NOTE
1 When the FANUC Handy File, FANUC Floppy
Cassette, FANUC FA Card, or FANUC Program
File Mate is used, specify C2.
2 If address C is not specified, ASCII code is used.
- Explanation
One character
a b1b2b3b4b5b6b7b8 c d1d2
a : Start bit (1 bit)
b : Information bit (8 bits)
c : Parity bit (0 or 1 bit)
d : Stop bit (1 or 2 bits)