B-63943EN-2/01 7.DEBUGGING FUNCTION
- 275 -
(6) Error information
Error information about the execution of the target P-CODE
macro is displayed.
ERROR a-bbbbbb-ccccc
a : 0 No error
1 An error occurred in macro statement specification.
2 An error occurred in NC statement specification.
bbbbbb : • For a macro statement, a variable number is
indicated. (For other than variables, 0 is indicated.)
• For an NC statement, a G code is indicated. (For
other than G code, 0 is indicated.)
When there is no error, 0 is indicated.
ccccc : Error No.
When there is no error, 0 is indicate Appendix A, "Error
No. List."
(7) Target
The currently selected target is indicated.
(8) Single-block execution status
For single-block execution, ON is indicated. For continuous
operation, OFF is indicated.
(9) Break function status
When the break function is enabled, ON is indicated. When the
break function is disabled, OFF is indicated.
(10) Break conditions
Program number by which a break is caused
Sequence number by which a break is caused
Number of blocks by which a break is caused
Iteration count by which a break is caused
(11) Macro variables (five variables)
The macro variables with set numbers are indicated. When P-
CODE macro execution is stopped by single-block execution or
the break function, the macro variables are re-displayed
automatically.
NOTE
1 The number of executed blocks is preset to 0 when
the program end command (M99<Pp>) has been
executed in the main program of the P-CODE
macro.
2 When no sequence number is assigned to a block
in the P-CODE macro, the sequence number of the
previously executed block is indicated.