6.MACRO EXECUTOR FUNCTION B-63943EN-2/01
- 250 -
Movement axis and direction variables for the rise time of the SKIP signal
(#8601 and #8608)
When the state of the SKIP signal (or, at a high-speed skip, the high-
speed skip signal) is changed from off to on, #8601 and #8608
indicate the axis that moved most recently and the direction of its
movement. #8601 corresponds to the 1st to 16th controlled axes in a
path, and #8608 corresponds to the 17th to 24th controlled axes in a
path.
#8601 and #8608 retains their values until the state of the SKIP signal
changes from off to on again. When the PMC internal relay (R area)
is turned off, both #8601 and #8608 are reset to 0, thereby disabling
this function.
NOTE
Any value can be written to neither #8601 nor
#8608.