B-63943EN-2/01 4.CONVERSATIONAL MACRO FUNCTION AND AUXILIARY MACRO FUNCTION
- 85 -
4.6 FATAL ERROR
An error may occur and execution may not be able to be continued
during execution of a conversational macro or auxiliary macro.
Such an error includes the case where a P-CODE macro program is
not found. In this case, the screen is forcibly switched to the
conversational macro screen and a message indicating that a fatal
error occurred is displayed.
If such an error occurs during execution of an auxiliary macro, the
control variable for executing an auxiliary macro (#8530) is preset to
0 and execution of the auxiliary macro is terminated.
The following items are displayed on the conversational macro
screen:
• Name of the P-CODE macro in which a fatal error occurred
• Message "ABNORMAL END"
• Error information
a-bbbbbb-ccccc
a : 0: No error occurred.
1: An error occurred in a macro statement command.
2: An error occurred in an NC statement command.
bbbbbb : • Variable number for a macro statement
(0 is displayed for other than a variable.)
• G code for an NC statement
(0 is displayed for other than a G code.)
When no error occurred, 0 is displayed.
ccccc : Error number
When no error occurred, 0 is displayed.
For details of the error, see Appendix A.1, "Error No.
List."
• Number of the program in which the error occurred
• Sequence number for which the error occurred