B–63010EN/02
4. DESCRIPTION OF PARAMETERS
139
#7
MDL3107
#6 #5 #4
SOR
#3 #2
DNC
#1 #0
NAM
[Data type] Bit
NAM Program list
0 : Only program numbers are displayed.
1 : Program numbers and program names are displayed.
DNC Upon reset, the program display for DNC operation is:
0 : Not cleared
1 : Cleared
SOR Display of the program directory
0 : Programs are listed in the order of registration.
1 : Programs are listed in the order of program number.
MDL Display of the modal state on the program display screen
0 : Not displayed
1 : Displayed (only in the MDI mode)
#7
JSP3108
#6
SLM
#5 #4
WCI
#3
PCT
#2 #1 #0
[Data type] Bit
PCT On the 7–pieces type soft key display program check screen and
12–pieces type soft key display position screen, T code displayed
0 : is a T code specified in a program (T).
1 : is a T code specified by the PMC (HD. T/NX. T)
WCI On the workpiece coordinate system screen, a counter input is:
0 : Disabled.
1 : Enabled.
SLM The spindle load meter is:
0 : Not displayed.
1 : Displayed.
>_ Sxxxxx Lxxx%
EDIT *** *** *** 12:34:56
[] [] [] [] []
Display of the
spindle load
meter
NOTE
1 This parameter is enabled only when the DPS parameter (bit
2 of parameter No.3105) is set to 1.
2 This is valid only for serial spindles.
JSP On the current position display screen and program check screen, jog feed is:
0 : Not displayed.
1 : Displayed.