4. DESCRIPTION OF PARAMETERS
B–63010EN/02
410
DRR For cutting feed per rotation in PMC axis control, the dry run function is:
0 : Disabled.
1 : Enabled.
IFV Override for each group in PMC axis control is:
0 : Disabled.
1 : Enabled.
MFD Output by each auxiliary function of the PMC axis control function is:
0 : Disabled.
1 : Enabled.
#7
8006
#6 #5 #4 #3 #2
IPA
#1
EML
#0
[Data type] Bit
EML When bit 0 (MLE) of parameter No. 8001 is set to 1, for PMC axes:
0 : The all axis machine lock signal and axis–by–axis machine lock
signals are disabled.
1 : The all axis machine lock signal is disabled and the axis–by–axis
machine lock signals are enabled.
IPA For PMC–dedicated axes:
0 : The in–position check is performed when no move command is
issued for the PMC axis.
1 : No in–position check is always performed.
#7
8008
#6 #5 #4 #3 #2 #1 #0
MIRx
[Data type] Bit axis
MIRx When a PMC axis control command is issued in mirror image mode, the
mirror image is:
0 : Not considered.
1 : Considered.
This parameter is valid when PMC signals MI1 to MI8 <bits 0 to 7 of
G106> are set to “1” or bit 0 (MIRx) of parameter No. 0012 is set to “1”.
8010 Selection of the DI/DO group for each axis controlled by the PMC
[Data type] Byte axis
[Valid data range] 1 to 4
Specify the DI/DO group to be used to specify a command for each
PMC–controlled axis.
Value Description
1 DI/DO group A (G142 to G153) is used.
2 DI/DO group B (G154 to G165) is used.
3 DI/DO group C (G166 to G177) is used.
4 DI/DO group D (G178 to G189) is used.