B–63010EN/02
4. DESCRIPTION OF PARAMETERS
309
#7
5700
#6 #5 #4 #3 #2 #1 #0
RTS
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
RTS When compensation is rewritten for the straightness compensation
function, it is enabled:
0 : After power–off.
1 : Immediately.
When this function is enabled, no power–off alarm is issued even if a
compensation parameter for straightness compensation (No. 5761 to
5784) is rewritten.
5711 Axis number of moving axis 1
5712 Axis number of moving axis 2
5713 Axis number of moving axis 3
[Data type] Byte
[Unit of data] Axis number (When 0, compensation is not performed.)
[Valid data range] 1 to Number of controlled axes.
Set the axis numbers of moving axes.
5721 Axis number of compensation axis 1 for moving axis 1
5722 Axis number of compensation axis 2 for moving axis 2
5723 Axis number of compensation axis 3 for moving axis 3
[Data type] Byte
[Unit of data] Axis number (When 0, compensation is not performed.)
[Valid data range] 1 to Number of controlled axes.
Set the axis numbers of compensation axes.
4.36
PARAMETERS OF
STRAIGHTNESS
COMPENSATION