B–63010EN/02
4. DESCRIPTION OF PARAMETERS
311
5861 Compensation point number a for each axis
5862 Compensation point number b for each axis
5863 Compensation point number c for each axis
5864 Compensation point number d for each axis
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Word axis
[Unit of data] Number
[Valid data range] 0 to 1023
These parameters set the compensation points for gradient compensation.
The points are set for the compensation point numbers for stored pitch
error compensation.
NOTE
Set compensation point numbers such that a < b < c < d is
satisfied.
5871 Compensation a at compensation point number a for each axis
5872 Compensation b at compensation point number b for each axis
5873 Compensation g at compensation point number c for each axis
5874 Compensation e at compensation point number d for each axis
[Data type] Word axis
[Unit of data] Detection unit
[Valid data range] –32767 to 32767
These parameters set compensation for each compensation point.
If pitch error compensation is applied at the same compensation point, the
valid data range is narrowed by the amount of compensation.
4.37
PARAMETERS OF
GRADIENT
COMPENSATION