4. DESCRIPTION OF PARAMETERS
B–63010EN/02
144
D10x The current positions (absolute position, relative position, machine
position, remaining travel, and travel by manual handle interrupt), and
workpiece zero–point offset are:
0 : Displayed as usual. (Not multiplied by ten.)
1 : Multiplied by ten, and displayed.
Example: The current position on the Y–axis is multiplied by ten and
displayed.
X 1.2345 → X 1.2345
Y 1.2345 → Y 12.345
Z 1.2345 → Z 1.2345
#7
MDC3116
#6
T8D
#5
COA
#4
FOV
#3 #2
PWR
#1 #0
MDP
[Data type] Bit
MDP The memory card input/output screen is:
0 : Not displayed.
1 : Displayed.
PWR Alarm No.100 (parameter enable) :
0 : Clear by
CAN
+
RESET
key
1 : Clear by
RESET
key
FOV In the field of specified feedrate F on the program check screen,
0 : The specified feedrate is displayed.
1 : (Specified feedrate) x (override) is displayed.
COA While an external alarm state is present or while an external message is
being displayed, automatic screen erasure is:
0 : Performed.
1 : Not performed.
NOTE
The value of this parameter set for path 1 is valid. The
values of path 2/3 or loader are invalid.
T8D T codes that are always displayed are displayed with:
0 : Four digits.
1 : Eight digits.
This parameter expands the T code display to eight digits for the
continuous S or T display (bit 2 (DPS) of parameter No. 3105 is set to 1).
MDC Maintenance information by operating soft key :
0 : All clear disable.
1 : All clear enable.