B–63010EN/02
4. DESCRIPTION OF PARAMETERS
157
OSC On the offset screen, offset value erasure by a soft key is:
0 : Enabled.
1 : Disabled.
MCK The system tape memory check function is:
0 : Not used.
1 : Used. (This setting is inhibited.)
#7
3206
#6 #5 #4
PHS
#3 #2 #1
MIF
#0
PCP
[Data type] Bit
PCP Program copy operation between two paths is
0 : Disabled.
1 : Enabled.
MIF Editing of the maintenance information screen is:
0 : Not prohibited.
1 : Prohibited.
PHS The selection of an operation history signal and parameters (No. 12801 to
No. 128900) are:
0 : Not linked.
1 : Linked.
#7
3207
#6 #5 #4 #3 #2 #1 #0
OM4
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit
OM4 A message displayed on the external operator message screen can have:
0 : Up to 256 characters, and just a single message can be displayed.
1 : Up to 64 characters, and up to four messages can be displayed.
#7
3208
#6 #5 #4 #3 #2 #1
COK
#0
SKY
[Data type] Bit
SKY The function key [SYSTEM] on the MDI panel is:
0 : Enabled.
1 : Disabled.
COK The automatic screen erase function is:
0 : Enabled.
1 : Disabled.