4. DESCRIPTION OF PARAMETERS
B–63010EN/02
142
#7
MS13113
#6
MS0
#5
DCL
#4
TCH
#3 #2 #1 #0
MHC
[Data type] Bit
MHC External operator message history data:
0 : Cannot be cleared.
1 : Can be cleared.
(Such data can be cleared using the [CLEAR] soft key.)
TCH Cursor movement on the touch panel is:
0 : Disabled.
1 : Enabled.
DCL The compensation function for the touch panel on the display is:
0 : Disabled.
1 : Enabled.
MS0, MS1 A combination of the number of characters preserved as external operator
message history data and the number of history data items is set according
to the table below.
MS1 MS0
Number of history
data characters
Number of history
data items
0 0 255 8
0 1 200 10
1 0 100 18
1 1 50 32
NOTE
When the values of MS0 and MS1 are changed, all preserved
external operator message history data is cleared.
#7
3114
#6
ICS
#5
IUS
#4
IMS
#3
ISY
#2
IOF
#1
IPR
#0
IPO
[Data type] Bit
IPO When the
POS
function key is pressed while the position display screen
is being displayed:
0 : The screen is changed.
1 : The screen is not changed.
IPR When the
PROG
function key is pressed while the program screen is being
displayed:
0 : The screen is changed.
1 : The screen is not changed.
IOF When the
OFFSET
SETTING
function key is pressed while the offset/setting screen is
being displayed:
0 : The screen is changed.
1 : The screen is not changed.