B-62694ENl03 OPERATION
2.FOR Series 15-B
2.2. I Description of Each Data
(a) Setting data of the Host Computer
(DATA SERVER SETTING- 1)
IPADDRESS IP address of the Host Computer’s Ether
board
( Ex. : “192.168.0.1” )
USER NAME User name of the Host Computer
( Max. 31 letters )
PASSWORD
Password for the above “USER NAME”
This password must be set.
(Max. 31 letters )
HOST
Working directory of the Host Computer in or
DIRECTORY to communicate with the Data Server
( Max. 127 letters )
I
You can input small letters in these items.
Please see the section “2.2.3 How to Input Small Letters”.
(b) Setting data of the Data Server
(DATA SERVER SETTING-2)
MAC
You must input the 12 alphanumerical letterr
ADDRESS
printed as the “ADR” at the seal on the Dats
Server’s face plate.
( Ex. : “080019ABCDEF” )
IP ADDRESS
IP address of the Data Server board
(Ex.: “192.168.0.2” )
MASK
Netmask for the network
ADDRESS
( Ex. : “255.255.255.0” )
CAUTION
1 If you change the above “(b) Setting data of the Data
Server” data, you must turn off the power of the CNC once.
2 You must input the 12 alphanumerical letters printed as the
“ADR” at the seal on the Data Server board into the MAC
address.
If you set the wrong address into the MAC address, it may
make a heavy obstacle on your network.
- 115-