2.FOR Series 15-B
OPERATION
29
.
MAINTENANCE OF DATA SERVER
B62694ENl03
If the trouble occurs at the Data Server function, the
contents of COMMON RAM for the interface between CNC
and Data Server can be saved into a file in order to examine
it.
This file is transferred to the Host Computer by using “2.3.5
Putting a NC Program” and the inside status of the Data
Server is checked by this file.
Procedure
(1)Press the function menu key in order to change the
softkeys into the function selection keys.
(z)If “MAINTENANCE OF DATA SERVER” screen is not
displayed, press the softkey [SERVICE] several times until
this screen is displayed.
(3)Press the operation menu key in order to change the
softkeys into the operation selection keys.
(4)Press the softkey [ SAVE 1.
@Press the softkey [ EXEC 1, so that the contents of
COMMON RAM are saved into the file as
“COMMON.RAM”.
(6)The blinking “SAVE” is displayed on the low of the screen
when saving.
MAINTENANCEOFDATASERVER 00001 NO0010
TOTAL SIZE
9999999999
READ POINTER
99999
WRITE POINTER
99999
>
MD1
kk* STOP k+ck* ***
*** 12:34:56 ***
SAVE
FORMAT CHKDSK MODE
CHAPTER
About meaning of each item, refer to the section “2.8
MAINTENANCE OF THE BUILT-IN HARD DISK”.
- 142-