1 .FOR Series 16/l 8-B/C, Series 16i/l8i-A
OPERATION
B-62694EN103
1.2. I
Description of Each Data
(a
.) Setting data of the Host Computer
(DATA SERVER SETTING- 1)
IPADDRESS IP address of the Host Computer’s Ethernel
board
( Ex. : “192.168.0.1” )
USER NAME User name of the Host Computer
( Max. 31 letters )
PASSWORD Password for the above “USER NAME”
This password must be set.
( Max. 31 letters )
HOST
Working directory of the Host Computer in order
DIRECTORY to communicate with the Data Server
( Max. 127 letters )
You can input small letters in these items.
Please see the section “1.2.3 How to Input Small Letters”.
(b) Setting data of the Data Server
(DATA SERVER SETTING-2)
MAC MAC address of the Data Server board
ADDRESS You must input the 12 alphanumerical let1
printed as the “ADR” at the seal on the D
Server board.
( Ex. : “080019ABCDEF”’ )
IP ADDRESS IP address of the Data Server board
( Ex. : “192.168.0.2” )
MASK Netmask for the network
ADDRESS ( Ex. : “255.255.255.0” )
CAUTION
1 If you change the above “(b) Setting data of the Data
Server” data, you must turn off the power of the CNC once.
2 You must input the 12 alphanumerical letters printed as the
“ADR” at the seal on the Data Server board into the MAC
address.
If you set the wrong address into the MAC address, it may
make a heavy obstacle on your network.
-58-