B-62694ENl03
OPERATION 2.FOR Series 15-B
When you want to get “nc_filel” file in the Host Computer
into the HDD as named “01234” by using “GET” command
of FTP, you specify “01234,nc-filel”.
In this case, the Data Server’s software changes “nc-filel”
into “nc_filel” and get “nc_filel” from the Host Computer
to the HDD.
NOTE
1
2
If the both NC parameters No.5028 and No.5029 are equal
to 0, then the NC parameters are considered to be set as
follows.
No.5028 = 32
(space)
No.5029 = 92 (Y)
If the both NC parameters No.5030 and No.5031 are equal
to 0, then the NC parameters are considered to be set as
follows.
No.5030 = 64
(W”)
No.5031 = 58
(I‘:“)
The NC parameters No.5032 and No.5033 don’t have
default values.
In these three pairs,
the smaller pair is available
preferentially. That is to say, if the same value is set in
No.5028, No.5030 and No.5032, the pair of No.5028 and
No.5029 is available.
In case of displaying the “DATA SERVER SETTING”
screen, the Data Server’s software exchanges the letters in
reverse and displays the setting data.
- 155--