(4)Input an O-number of the List-File from the MD1 keys.
In this List-File, O-numbers of NC programs that you will
register into the Host Computer are specified.
[ FORMAT ]
0
****
0
**** : a List-File name stored in the HDD
(
**** is the integer of four digits)
NOTE
1 The List-File name must be named “O****“.
2 You must specify O****
that is registered in the HDD.
And the O-number specified in this List-File must be
registered in the HDD too.
If the specified O-number doesn’t exist in the HDD, an
error occurs.
(@Press the softkey [ EXEC 1.
(6)The blinking “L-PUT” is displayed on the right and low of
the screen when transferring NC programs.
(7)You can stop transferring NC programs by pressing the
softkey [ STOP 1.
CAUTION
1 This List-Put function can be stopped, but the stopping unit
is a file. That is to say, when the transmission of one file is
finished, if the softkey [STOP] is pressed, this function is
stopped.
2
3
Therefore, it may take many time from pressing the softkey
[ STOP] until stopping the service actually.
When stopping this List-Put function, NC programs
transmitted to the Host Computer are kept registered.
If an error occurs in this function, “PUT ERROR” is
displayed on the left and low of the screen.
Confirm the problem by referring to the section “1.11
ERROR MESSAGE”. About error messages, refer to the
section “APPENDIX A. TABLE OF ERROR MESSAGES”.
And in this case, NC programs transmitted to the Host
Computer until an error occurs are kept registered.
-83-