FANUC Series 30i/31i-MODEL A/31i-MODEL A5
Workpiece Setting Error Compensation
-79634E
12
/
Ed. Date Design Description
Date Feb.08.’05 Design. Apprv.
page
Title
Draw
No.
- Least input increment of data and valid data range
[About errors ∆x, ∆y, and ∆z]
The unit of data is the unit of input, and follows the least input increment for the
reference axis specified by parameter No. 1031.
- For metric input
Unit system of
reference axis
IS-A IS-B IS-C IS-D IS-E
Least input
increment (mm)
0.01 0.001 0.0001 0.00001 0.000001
Maximum settable
value (mm)
±999,999.99 ±999,999.999 ±99,999.9999 ±9,999.99999 ±999.999999
- For inch input
Unit system of
reference axis
IS-A IS-B IS-C IS-D IS-E
Least input
increment (inch)
0.001 0.0001 0.00001 0.000001 0.0000001
Maximum settable
value (inch)
±99,999.999 ±99,999.9999 ±9,999.99999 ±999.999999 ±99.9999999
[About errors ∆a, ∆b, and ∆c]
With parameter No. 11201, the number of decimal places of the least input
increment can be specified.
Parameter No. 11201
1 2 3 4
Least input increment (deg) 0.1 0.01 0.001 0.0001
Maximum settable value
(deg)
±99,999,999.9 ±9999,999.99 ±999,999.999 ±99,999.9999
Parameter No. 11201
5 6 7 8
Least input increment (deg) 0.00001 0.000001 0.0000001 0.00000001
Maximum settable value
(deg)
±9,999.99999 ±999.999999 ±99.9999999 ±9.99999999
Note, however, that a value from 1 to 8 can be specified in parameter No. 11201.
If a value not within the specifiable range is specified in parameter No. 11201,
the least input increment of the reference axis is followed.
Unit system of
reference axis
IS-A IS-B IS-C IS-D IS-E
Least input
increment (deg)
0.01 0.001 0.0001 0.00001 0.000001
Maximum
settable value
(deg)
±999,999.99 ±999,999.999 ±99,999.9999 ±9,999.99999 ±999.999999