B-65232EN/03 FANUC AC SERVO AMPLIFIER β series 5.POWER SUPPLY
- 165 -
5.3 POWER TRANSFORMER FOR EXPORTS
Use power transformer for an export when this servo amplifier unit is
used at a site where the line voltage is other than 200 to 240 VAC.
5.3.1 Specification
Table 5.3.1 Specification of power transformer
Ordering drawing number
A80L-0022-0005 A80L-0024-0006 A80L-0026-0003 A80L-0028-0001
FANUC drawing number
A80L-0022-0005 A80L-0024-0006 A80L-0026-0003 A80L-0028-0001
Rated capacity
2.2kVA 3.5kVA 5kVA 7.5kVA
200/220/230/240VAC (∆ connection)
380/415/460/480/550VAC (Y connection)
Rated primary voltage
±15%, 50/60Hz±2Hz; 3φ
Rated secondary voltage
210VAC
Rated secondary current
6.1A 9.6A 13.7A 20.6A
Voltage regulation at the secondary
2%
Voltage deviation at the secondary
±3%
Connection
∆-∆ connection or Y-∆ connection
Insulation
Class B (maximum allowable temperature : 130
°C)
Ambient temperature
-20 to 55
°C
Allowable temperature rise
135deg
Relative humidity
Max. 95%RH
Type
Dry type, natural air cooling type
Dielectric withstand voltage
2300VAC, for 1 minute
Weight
Max. 21kg Max. 27kg Max.36kg Max. 42kg
Outline drawing
Fig. 8.1.3
Connection diagram