PROGRAMMING
B–62094E/04
15. CUSTOM MACRO
137
System variables can be used to read and write internal controller data
such as tool compensation values and current position data. Note,
however, that some system variables can only be read. System variables
are essential for automation and general–purpose program development.
Signals can be exchanged between the programmable machine controller
(PMC) and custom macros.
Table 15.2(a) System variables for interface signals
Variable
number
Function
#1000–#1015
#1032
A 16–bit signal can be sent from the PMC to a custom
macro. Variables #1000 to #1015 are used to read a sig-
nal bit by bit. Variable #1032 is used to read all 16 bits of
a signal at one time.
#1100–#1115
#1132
A 16–bit signal can be sent from a custom macro to the
PMC. Variables #1100 to #1115 are used to write a signal
bit by bit. Variable #1132 is used to write all 16 bits of a
signal at one time.
#1133 Variable #1133 is used to write all 32 bits of a signal at one
time from a custom macro to the PMC.
Note, that values from –99999999 to +99999999 can be
used for #1133
.
For detailed information, refer to the connection maintenance manual
(B–62095E).
System variables #1200 to #1959 can be used to write and read data to and
form the PMC D/R area.
The system variables area associated with the location in the D/R area, as
follows :
#1200 to #1219 : Variable time (T)
#1220 to #1224 : Keep relay (K)
#1225 to #1244 : Counter (C)
#1245 to #1709 : Data table (D)
#1710 to #1959 : Internal relay (R)
15.2
SYSTEM VARIABLES
Explanations
D Interface signals
D PMC D/R area
information