APPENDIX
B–62094E/04
G. ALARM LIST
443
The details of spindle alarm No. 750 are displayed in the diagnosis display
(No. 409) as shown below.
#7 #6 #5 #4 #3 #2 #1 #0
SPE S2E S1E SHE409
SPE 0 : In the spindle serial control, the serial spindle parameters
fulfill the spindle unit startup conditions.
1 : In the spindle serial control, the serial spindle parameters do
not fulfill the spindle unit startup conditions.
S2E 0 : The second spindle is normal during the spindle serial control
startup.
1 : The second spindle was detected to have a fault during the
spindle serial control startup.
S1E 0 : The first spindle is normal during the spindle serial control
startup.
1 : The first spindle was detected to have a fault during the
spindle axis serial control startup.
SHE 0 : The serial communications module in the CNC is normal.
1 : The serial communications module in the CNC was detected
to have a fault.
9) System alarms
(These alarms cannot be reset with reset key.)
Number Message Contents
900 ROM PARITY ROM parity error (CNC/MACRO/LADDER/Servo)
Rewrite the flash ROM with the indicated ROM number.
910 SRAM PARITY: (LOW) RAM parity error in the tape memory RAM module. Clear the
memory or replace the base PCB.
After this operation, reset all data including the parameters.
911 SRAM PARITY : (HIGH) RAM parity error in the tape memory RAM module. Clear the
memory or replace the base PCB.
After this operation, reset all data including the parameters.
920 SERVO ALARM (1/2 AXIS) Servo alarm (1st or 2nd axis). A watchdog alarm or a RAM parity
error in the servo module occurred.
Replace the servo control module on the main CPU board.
924 SERVO MODULE SETTING
ERROR
The digital servo module is not installed.
Check that the servo control module or servo interface module on the
main CPU board is mounted securely.
930 CPU INTERRUPUT CPU error (abnormal interrupt)
The main CPU board is faulty.
950 PMC SYSTEM ALARM Fault occurred in the PMC. The PMC control module on the main
CPU board may be faulty.
951 PMC–PA WATCH DOG ALARM Fault occurred in the PMC–PA (watchdog alarm).
970 NMI OCCURRED IN BOC RAM parity error or NMI occurred in the PMC–PA module.
971 NMI OCCURRED IN SLC An alarm condition occurred in the interface with an I/O unit. Check
that the PMC control module on the main CPU board is conneted to
the I/O unit securely. Check that the I/O unit is supplied with power
and that the interface module is intact.
973 NON MASK INTERRUPT NMI occurred for an unknown reason.
D The details of spindle