B-63942EN/02 NC FUNCTION 5.PROGRAM INPUT
- 165 -
5.7 MAXIMUM COMMAND VALUES
The basic addresses and specifiable value ranges are indicated below.
Note, however, that the information below represents restrictions
imposed by the CNC, and is totally irrelevant to the restrictions
imposed by each machine.
Table 5.7 (a) Major addresses and ranges of command values
Function Address Input in mm Input in inch
Program number O
(*1)
1 to 99999999 1 to 99999999
Sequence number N
1 to 99999999 1 to 99999999
Preparatory function G
0 to 99.9 0 to 99.9
Increment system IS-A
±
999999.99 mm
±
999999.99 deg.
±
99999.999 inch
(*3)
±
999999.99 deg.
Increment system IS-B
±
999999.999 mm
±
999999.999 deg.
±
99999.9999 inch
(*3)
±
999999.999 deg.
Increment system IS-C
±
99999.9999 mm
±
99999.9999 deg.
±
9999.99999 inch
(*3)
±
99999.9999 deg.
Increment system IS-D
±
9999.99999 mm
±
9999.99999 deg.
±
999.999999 inch
(*3)
±
9999.99999 deg.
Dimension
word
Increment system IS-E
X,Y,Z,U,V,W,A,B,C,I
,J,K,R
(*2)
±
999.999999 mm
±
999.999999 deg.
±
99.9999999 inch
(*3)
±
999.999999 deg.
Increment system IS-A
0.01 to
999000.00mm/min
0.001 to
96000.000inch/min
Increment system IS-B
0.001 to
999000.000mm/min
0.0001 to
9600.0000inch/min
Increment system IS-C
0.0001 to
99999.9999mm/min
0.00001 to
4000.00000inch/min
Increment system IS-D
0.00001 to
9999.99999mm/min
0.000001 to
400.000000inch/min
Feed per
minute
Increment system IS-E
F
0.000001 to
999.999999mm/min
0.0000001 to
40.0000000inch/min
Feed per revolution F
0.001 to 50000mm/rev 0.0001 to 50.0000inch/rev
Spindle speed function S
(*4)
0 to 99999999 0 to 99999999
Tool function T
(*4)
0 to 99999999 0 to 99999999
M
(*4)
0 to 99999999 0 to 99999999
Auxiliary function
B
(*4)
0 to 99999999 0 to 99999999
Offset number (M series only) H, D
0 to 999 0 to 999
Increment system IS-A
0 to 999999.99 sec 0 to 999999.99 sec
Increment system IS-B
0 to 99999.999 sec 0 to 99999.999 sec
Increment system IS-C
0 to 9999.9999 sec 0 to 9999.9999 sec
Increment system IS-D
0 to 999.99999 sec 0 to 999.99999 sec
Dwell
Increment system IS-E
X, U (T series only)
0 to 99.999999 sec 0 to 99.999999 sec
Dwell P
1 to 99999999
1 to 99999999
Designation of a program number P
1 to 99999999 1 to 99999999
L
1 to 99999999 1 to 99999999
Number of sub program repetitions
P
0 to 9999 0 to 9999
*1 In ISO code, the colon ( : ) can also be used as the address of a
program number.