PROGRAMMING15. CUSTOM MACRO
B–64114EN/01
262
Table 15.2 (g) System variable (#3004) for automatic
operation control
#3004 Feed hold Feedrate Override Exact stop
0
Enabled Enabled Enabled
1
Disabled Enabled Enabled
2
Enabled Disabled Enabled
3
Disabled Disabled Enabled
4
Enabled Enabled Disabled
5
Disabled Enabled Disabled
6
Enabled Disabled Disabled
7
Disabled Disabled Disabled
D When the power is turned on, the value of this variable is 0.
D When feed hold is disabled:
(1)When the feed hold button is held down, the machine stops in the
single block stop mode. However, single block stop operation is
not performed when the single block mode is disabled with
variable #3003.
(2)When the feed hold button is pressed then released, the feed hold
lamp comes on, but the machine does not stop; program execution
continues and the machine stops at the first block where feed hold
is enabled.
D When feedrate override is disabled, an override of 100% is always
applied regardless of the setting of the feedrate override switch on the
machine operator’s panel.
D When exact stop check is disabled, no exact stop check (position check)
is made even in blocks including those which do not perform cutting.
Settings can be read and written. Binary values are converted to decimals.
#9 (FCV) : Whether to use the FS15 tape format conversion capability
#5 (SEQ) : Whether to automatically insert sequence numbers
#2 (INI) : Millimeter input or inch input
#1 (ISO) : Whether to use EIA or ISO as the output code
#0 (TVC) : Whether to make a TV check
#15 #14 #13 #12 #11 #10 #9 #8
FCV
Setting
#7 #6 #5 #4 #3 #2 #1 #0
SEQ INI ISO TVC
Setting
#3005
D Settings