31. SAFETY FUNCTIONS
B–63002EN/01
NC FUNCTION
340
G22 X_ Z_ I_ K_ ;
On/off of stored stroke check 2 is commanded by program as follows:
G22 : Stored stroke check function on
G23 : Stored stroke check function off
This function calculates the movement end point at the start of movement
in a block, during automatic operation, based on the current machine
position and the specified amount of travel, to check whether the end point
falls within the inhibited area for stored stroke limit 1, 2, or 3. If the end
point falls within an inhibited area, movement for that block is stopped
immediately upon the start of movement and an alarm is issued.
Start point
End point
a
Stops at point a according to stored
stroke limit 1 or 2.
Inhibited area for stored stroke limit 1
or 2
Start point→Stops immediately upon the start of
movement due to stroke limit check
being performed before movement.
End
point
Inhibited area for stored stroke limit 1
or 2
Example 1)
NOTE
This function checks only whether the end point falls within
an inhibited area. It does not check whether the tool passes
through an inhibited area between the start and end points.
However, an alarm is issued upon a tool’s entering an
inhibited area according to stored stroke limit 1, 2, or 3.
Format
31.2.6
Stroke Limit Check
Before Movement