B–63682EN/01
17. MEASUREMENT FUNCTIONS
NC FUNCTION
119
By commanding axis move after G33, linear interpolation can be
commanded like in G01. If an external skip signal is input during this
command, the remainder of this command is cancelled, and program
skips to the next block.
G33 is a one-shot command and is valid for the commanded block only.
100.0
50.0
Skip signal input
(300, 100)
Skip signal input
Actual movement
With no skip signal input
G33 G91 X100.0 F100 ;
Y50.0 ;
G93 G90 X200.0 F100 ;
X300.0 Y100.0 ;
Coordinate value when skip signal is on, is stored in the system variables
#5061 - #5068 of the customer macro, so this function can also be read
with the customer macro function.
#506n: n–th axis coordinate value (n= 1 to 8)
As the skip function can be used when move amount is not clear, this
function can be used for:
D Tool measurement with tactile sensor.
Delay and error of skip signal input is 0–2 msec at the NC side (not
considering those at the PMC side).
This high-speed skip signal input function keeps this value to 0.1 msec
or less, thus allowing high precision measurement. This signal is
connected directly to the NC; not via the PMC.
17.1
SKIP FUNCTION
(G33)
17.2
HIGH-SPEED SKIP
SIGNAL INPUT